danaxhn.blogg.se

Honeywell galaxy 48
Honeywell galaxy 48












  1. HONEYWELL GALAXY 48 MOD
  2. HONEYWELL GALAXY 48 CODE

The MK8 is the same technology as the MK7 - only a facelift.Īs above, always remember to power down the keypad if changing the address, then 'esc' exit from engineering mode to re-enumerate the RS485 slave devices. If it's powered by the Power RIO, then only the 0V will be common power wise with the main panel. There should be no reason that the garage keypad should be any different. The address mapping (rotary dial first) is:ī (Address 15) (used by Ethernet module if fitted)Ĭ (Address 16) (used by ISDN module if fitted)ĭ (Address 17) (used by External RS232 module if fitted)Į (Address 18) (used by External Telecoms module if fitted) This depends if you have peripheral devices fitted, as peripheral devices have multiple devices, emulating keypads internally. As above, on the Dimension 48, you can consume addresses B to F for additonal regular keypads. There are only 3 MAX addresses on the GD48 for keyprox (combined keypad and max). The keyprox MAX addresses are not the same as the keypad addresses. The keypad is now configured into the system.

HONEYWELL GALAXY 48 MOD

NOTE: If adding a keyProx to the system, the message 2 MOD ADDED will be displayed to indicate that both a keypad and MAX have been added to the system.ĩ. In this case all connections and addresses should be rechecked. NOTE: If this message is not displayed, the keypad is not communicating with the control panel and has not been configured into the system. Press the esc key the keypad returns to the unset banner. The Mk7 keypad displays the message 1 MOD.

HONEYWELL GALAXY 48 CODE

Exit engineer mode - engineer code + esc:Ĩ. Connect + and – terminals of the keypad to a power supply.ħ. Connect the RS485 (AB) line of the keypad in parallel with the RS485 (AB) line of the existing keypads.Ħ. Note: A new keypad can only be configured into an existing Galaxy system from engineer mode.ĥ. Connect the keypad to the system - refer to the Keypad Installation Procedure. Ensure that the keypad has a valid address.ģ. Ensure that the keypad to be added has a unique address from the other keypads on the system.Ģ. When adding a keypad to an existing system, the following points must be considered:ġ. NOTE: On Line 1, keypad addresses B, C, D and E are not available if the Ethernet, ISDN, RS232 or Telecom modules respectively are fitted. An engineer keypad can also be used at address F. It is possible to add additional keypads at any unused comms module addresses (B, C, D and E) as detailed in the following NOTE. Each keypad must be assigned a unique address for its line. NOTE: Any change to the keypad address must be made when the power is disconnected from the keypad.Īddresses are set by means of a rotary switch on the PCB. The address switch assigns a hexadecimal address value to the keypad. Have you set the address on the keypad itself (the rotary switch on the back)?Ī 16-way rotary address switch is used to address Galaxy LCD keypads. So you can have a mixture of keyprox/non keyprox ones on the same line. You can have 8 keypads of which up to 3 of those can be keyprox ones. just a cosmetic thing?Īppreciate a bit if a specific one but any help appreciated. Anyone know if v7 and v8 are pretty much interchangeable - I.e. I currently have v7 keypad and if buying new ones anyway was going to just get v8 ones. So if I swap out the keyprox ones for non-keyprox it should work (as we have less than. it can take up to 8 as long as ever one is non-keyprox. I'm thinking problem is that I have keyprox ones already and it can't take a mix like this? i.e. I've lost faith a bit and can't believe there is not a definitive answer to how this works. Our local installer seems pretty sure it should take a mix of keyprox and non keyprox (3 keyprox and then 1 more non-keyprox) but can't get it to address the keypad. It doesn't say if this is either / and / or though! Honeywell support don't seem sure either which seemed a bit strange as it can't be that uncommon. The spec for the system is 8 non keyprox, 3 keyprox (says 8 and then 3 in brackets). I am wanting to add a keypad into our garage which will make 4 in total on the system. I have a Honeywell Galaxy Dimension GD-48.














Honeywell galaxy 48